Introduction of Microwave Vacuum Dryer
Microwave vacuum drying equipment combines two different technologies to create specific conditions for drying very sensitive products. While microwaves deliver gentle and uniform heat to the material, a vacuum atmosphere allows using a lower drying temperature. Vacuum microwave drying is highly suitable for processing pharmaceutical products and a wide range sensitive food products as well as chemical reaction.
Features of Vacuum Equipment Specialized in Chemical Products Drying
1. The whole equipment is made of stainless steel, corrosion-resistant and easy to clean.
2. Vacuum degree is less than -0.09Mpa, automatically controlled.
3. The core components of microwave system is self-researched, up to international standard.
4. Automatic PLC control system can realize data storage, output and print.
5. The microwave drying equipment adopts continuously variable transmission which is energy saving and ensures a reliable working process.
6. Non-contact Infrared temperature measurement technology, accurate and easy to control.
7. Special design drainage system greatly improves working efficiency.
8. Microwave leakage is ≤1mW/cm2, less than state standard(≤5mW/cm2)
Application of Vacuum Microwave Dryer Oven

Technical Data of Microwave Vacuum Drying Machine
Model | AZS-MV-6 | AZS-MV-9 | AZS-MV-12 | AZS-MV-20 | AZS-MV-30 |
Voltage | 380V, 50Hz | ||||
Frequency | 2450±50MHz | ||||
Appearance | Silver White Stainless Steel | ||||
Transmission Mode | Rotary Type Pallet | ||||
Magnetron Power | 1kW/set | ||||
Vacuum Degree | -0.084~-0.091MPa | ||||
Output Power(kW) | 6 | 9 | 12 | 20 | 30 |
Overall Size(m) | 1.45×1.2×1.7 | 1.45×1.2×1.7 | 1.6×1.3×1.7 | 2.0×1.6×1.7 | 2.3×2.0×1.7 |
Magnetron Cooling Method | Air cooling or water cooling | ||||
Operation Method | PLC touch screen control and operation | ||||
Material | SS304, thickness with 11mm | ||||
Microwave Leakage | ≤1 | ||||
Vacuum Pump Power | 1.8kW | 2.2kW | 4.5kW | 5.5kW | 7.5kW |
Speed of tray | 3r/min | ||||
Safety Device | 1, Fault alarm system; 2, Safety warning digns; 3, Limit switches. | ||||
Trays | 3 | 3 | 6 | 8 | 10 |
Control system | PLC control with touch scren, Temperature, Time, Microwave power and Moisture are adjustable and control. |
Attentions to Vacuum Microwave Drying
◆ you should process the same material in every batch.
◆ the material size should be similar
◆ disperse the material instead of piling up.
◆ no metal in the material
◆ the microwave equipment should not work without loading.